Instance: Holter_electrocardiography_24_hour

Types
Own Slots
  Slot Name Value
CanDetect Acute_myocardial_ischemia, Chronic_ischemic_heart_disease, Drug_abuse, Any_arrhythmia, Cardiac_dyssysnchrony, Reduced_heart_rate_variability
CouldBeRelatedTo Chronic_heart_failure, Any_arrhythmia
Cui C0013801
Definition  
ExcludesDiagnosis  
IfAbnormalThenPrognosis  
IfNormalThenPrognosis Good
IfNormalThenReview  
IfNormalThenStronglyReconsider Chronic_heart_failure
Invasive false
Measures ST_segment_depression, Twenty_four_heart_rate_maximum_in_beats_per_min, Three_or_more_ventricular_ectopic_beats_in_N_per_24h, Three_or_more_supraventricular_ectopic_beats_maximum, SDANN_in_ms, Three_or_more_supraventricular_ectopic_beats_in_N_per_24h, Twenty_four_heart_rate_mean_in_beats_per_min, Ventricular_couples_in_N_per_24h, Grade_II_AV_block_type_II, Grade_III_AV_block, Three_or_more_ventricular_ectopic_beats_maximum, Isolated_supraventricular_ectopic_beats_in_N_per_24h, Night-time_heart_rate_minimum_in_beats_per_min, Maximum_heart_rate_in_beats_per_min, SDNN_in_ms, ST_segment_elevation, Maximum_R-R_interval_in_s, Daytime_heart_rate_mean_in_beats_per_min, Left_bundle_branch_block_measurement, Night-time_heart_rate_mean_in_beats_per_min, rMSSD_in_ms, Twenty_four_heart_rate_minimum_in_beats_per_min, pNN50_in_percentage, Daytime_heart_rate_maximum_in_beats_per_min, Grade_II_AV_block_type_I, Daytime_heart_rate_minimum_in_beats_per_min, Grade_I_AV_block, Supraventricular_couples_in_N_per_24h, Right_bundle_branch_block_measurement, Sinus_rhytm_measurement, Night-time_heart_rate_maximum_in_beats_per_min, Heart_rate_variability, Isolated_ventricular_ectopic_beats_in_N_per_24h
NotUsedWhenDiagnosisIsPresent  
SupportsDiagnosis Reduced_left_ventricular_ejection_fraction
Synonyms Holter
Test_affected_by  
TestCharacteristic Additional_test
UMLSSynonyms Holter_monitoring
UsedIfTestAbnormal  
UsedInsteadOfTest  
UsedWithOtherTest  

  ^ back to top